Specifications:
Loop Frequency:
Four
frequencies (normally in the range of 20 to 100 kHz) are dip switch selectable
from the front panel
Reset:
Changing any dip switch position
(except SW 1 & SW 2: frequency selection) will reset the detector. After
changing the Frequency selection switches, the detector will require a RESET.
Reset will clear the loop fault memory.
Sensitivity:
Vehicle detection results when
a negative change in loop inductance (-DL/L) exceeds
the sensitivity setting. Four detection sensitivity levels are dip switch selectable
from the front panel.
|
Sensitivity
|
-DL/L
|
|
Low
|
0.32%
|
|
Med Lo
|
0.16%
|
|
Med Hi
|
0.08%
|
|
High
|
0.02%
|
Sensitivity Boost:
An external dip switch setting
may be turned on to increase sensitivity during the detect period. When a vehicle
enters the loop, the detector sensitivity is boosted to a higher level than the
vacant loop setting. The boosted sensitivity remains throughout the detect period.
When the vehicle leaves the loop, the sensitivity returns to the vacant loop setting.
This feature helps prevent dropouts during the passage of high bed vehicles and
is particularly useful in sliding gate situations.
Output Configurations:
The output is selectable for "TruePresenceÔ
" , "Limited Presence" , "Pulse on Entry" , or "Pulse
on Exit". TruePresenceÔ will hold the call for
as long as the vehicle is present and power is not removed or reset applied. Limited
presence will typically hold the CALL output for about 1-3 hours. The TruePresenceÔ
time applies only for normal size automobiles and trucks and for normal size loops
(approx. 12 sq. ft. to 120 sq. ft.). When in the pulse mode, the 250 millisecond
pulse can be selected as either pulse on entry (when a vehicle enters the
loop) or pulse on exit (when a vehicle exits the loop).
CALL Delay:
A 2-second delay can be activated
by an internal dip switch. Output delay is the time the detector outputs are delayed
after a vehicle first enters the loop detection area and is indicated by the front
panel detect LED flashing at 4 Hz with a 50% duty cycle. If the 2-second output
delay feature is activated, the output relays will only be turned on after 2 seconds
has passed with a vehicle continuously present in the loop detection area. If
a vehicle leaves the loop detection area during the 2-second delay interval, detection
is aborted and the next vehicle entering the loop detection area will initiate
a new full 2-second delay interval.
Output CALL Memory:
When power is removed for 2 seconds
or less, the detector automatically "remembers" if a vehicle was present
over the loop. When power is restored, the detector will continue to output a
call until the vehicle leaves the loop. (Power loss or dips of 2 seconds or less
will not drop the CALL).
Power Status Indicator:
A green super-high-intensity light
emitting diode (LED) indicates power status during normal detector operation.
When the green (PWR) LED is on, the power to the detector is normal. When power
drops approximately 20% from nominal, the green LED turns off and the detector
remains operational. When power drops approximately 25% from nominal, the green
LED is off and the "line" voltage is not sufficient to operate the detector
Detect Status Indicator:
The red detect LED is steady on
while a vehicle is being detected. The detect LED will flash at a 4 Hz rate with
a 50% duty cycle while timing out the 2-Second Call Delay.
Loop FAIL Monitor Indicator:
If the total inductance of the
detector input network goes out of the range specified for the detector or suddenly
changes more than +/-25% the detector will enter FAIL mode.
The red FAIL LED will either begin flashing with a 50% duty
cycle once per second for a shorted loop condition or will be on continuously
for an open loop condition. These indicator conditions will continue until the
inductance returns to its previous value at which time the detector output will
automatically resume normal operation, and the red FAIL
LED will flash at a distinctive rate (a burst of 3 flashes once per second) to
indicate an intermittent loop fault has occurred and corrected. The flash rate
will continue until another loop fault occurs, the detector is reset, or the detector
loses power. [The detector input network, consists of the loop or loops plus the
feeder cable (lead-in or home run) up to the connector on the detector].
FAIL SAFE
Operation:
When the loop fails or power is
removed, continuity exists between Common & N.O. for presence mode. Continuity
exists between Common & N.C. for pulse mode.
FAIL SECURE
Operation:
When the loop fails or power is
removed, continuity exists between Common & N.C. for both presence and pulse
modes.
Self Tuning:
Automatically tunes to loop within
2 seconds after application of power or reset. 30 seconds of operation is required
before full sensitivity and presence time is reached following application of
power or a reset.
Environmental Tracking:
Fully self-compensating for environmental
changes and loop drift over the full temperature range and the entire loop inductance
range.
Loop Inductance Range:
20 to 1000 mH
with Q factor of 5 or greater.
Loop Feeder Length:
Up to 2500 feet (762 m) maximum with
proper feeder cable and appropriate loops.
Loop Input:
Transformer isolated. The minimum capacitance
added by the detector is 0.068 mF.
Grounded Loop Operation:
The loop isolation transformer
allows operation with poor quality loops (which may include a single point short,
or leakage, to ground).
Lightning Protection:
The detector can tolerate, without
damage, a 10 mF capacitor charged to 1,000 Volts being
discharged directly into the loop input terminals, or a 10 mF
capacitor charged to 2,000 Volts being charged between either loop terminal and
earth ground.
Internal Circuitry Isolation:
All internal electronic circuitry
is isolated from all external circuitry. Power is isolated by means of the power
transformer. The loop is isolated by means of the loop isolation transformer.
The outputs are isolated by means of the output relays.
Automatic Reset Internal Fuse:
When 120VAC is applied to 24VAC
models, the automatic internal fuse will open. The fuse will automatically reset
when power is removed for 3 seconds. Source voltage should be verified before
reinstalling.
Relay Rating(s):
The relay contacts are rated for
6 Amp max, 150 VDC max, 300 VAC max and 180 Watts max switched power.
Ruggedized Construction:
The enclosure is high temperature
rated lexan plastic. Printed circuit boards are 0.062 in FR4 material with double
sided 2-oz copper and plated through-holes.
Operating Temperature:
-40°
F to + 180° F. Meets or exceeds NEMA specifications.
Power(s):
18 to 32 VAC, 50/60
Hz., 4.0 Watts max
89 to 135 VAC, 50/60 Hz., 4.0 Watts
max
176 to 288 VAC., 50/60 Hz., 4.0 Watts
max
10 to 16 VDC, 80 mA max
20 to 34 VDC, 50 mA max.
Fuse(s):
24 VAC power: 120
mA, Polymeric
120 VAC power: 3/8 Amp, Slo-Blo
240 VAC power: 3/8 Amp, Slo-Blo
12 VDC power: Current limited
24 VDC power: Current limited.
Size
1.55 inches (3.90 cm.) Wide x
2.50 inches (6.35 cm.) High x 4.20 inches (10.65 cm.) Deep, including rear connector
Weight
Approx. 7.6 oz. (215.46 gm.).
Connector:
Rear mount 11 Pin male "Amphenol"
connector (86CP11).
Pin Assignments
| PIN |
FUNCTION |
| 1 |
Power, Hot or (+) |
| 2 |
Power, Neutral or (-) |
| 3 |
No Connection |
| 4 |
No Connection |
| 5 |
Output, Common (Com.) |
| 6 |
Output, Normally Open
(N.O) |
| 7 |
Loop |
| 8 |
Loop |
| 9 |
No Connection |
| 10 |
Output, Normally Closed
(N.C.) |
| 11 |
No Connection |
Note:
* Relay contacts are shown with power applied, loop(s) connected, and
no vehicles present.
Models & Configurations
| Model |
Voltage |
Operation |
| AX-3 |
120 VAC |
FAIL
SAFE |
| AX-3-S |
120 VAC |
FAIL
SECURE |
| AX-7 |
24 VAC |
FAIL
SAFE |
| AX-7-S |
24 VAC |
FAIL
SECURE |
| AX-8 |
240 VAC |
FAIL
SAFE |
| AX-8-S |
240 VAC |
FAIL
SECURE |
| AX-23 |
12 VDC |
FAIL
SAFE |
| AX-23-S |
12 VDC |
FAIL
SECURE |
| AX-24 |
24 VDC |
FAIL
SAFE |
| AX-24-S |
24 VDC |
FAIL
SECURE |
Factory Default Settings (External DIP Switch):
Sensitivity Level: Med Lo
Output Configurations: Presence
Sensitivity Boost: OFF
Factory Default Settings (Internal DIP Switch):
True Presence (Infinite)
2-Second CALL
Delay: OFF
Notes:
* CALL Memory
is always on. There is no switch setting for this feature.
* Please specify correct model number
for FAIL-SAFE or FAIL-SECURE when
ordering.
** Specifications are subject to change to reflect
improvements and upgrades.