AIPHONE Compatibility Questions Issues regarding product compatibility
are listed below in question/answer form. If your compatibility issue is not
resolved here please submit a question directly to Technical Support. Open Voice Products
LEF System
Q: Is the LEF System compatible
with the IE/IF Door Stations?
A: NO. Use
LE- or LS-series door stations or LE-series sub stations only.
Q: Are the LEF System
masters compatible with the LEM System masters?
A: NO, although both use the
LE-Series sub stations.
Q: Can the LEF System
be connected to a Paging System?
A: YES, with the BA-1
Paging Adapter and the appropriate sized amplifier.
Q: Are there any multiple
call door stations for the LEF System?
A: YES, the LE-B2, LE-B4,
LE-B6 and LE-B10, listed as Special Order Products.
We have also introduced the LE-GA series, available with 2 ~ 8 call buttons
(LE-GA2 ~ LE-GA8).
Q: Is the NE-NVP/B Vandal
Resistant Door Station compatible with the LEF System?
A: NO. Use the LS-NVP/B.
Q: Is the RY-AC External
Signaling Relay compatible with the LEF System?
A: YES. See the Systems Modification
Manual for connection information.
Q: Is the SP-5N Ceiling
Speaker compatible with the LEF System?
A: NO, use the SP-20N
20 ohm speaker with an
NP-25V non-polarized capacitor (33mfd, 25V, Non-polarized).
Q: Is the LEF System compatible
with the MY Video Cameras?
A: YES, using the MYW-P1L,
MYW-P3L, or MYW-P10L Video Door Adapters.
Q: What is the difference
between the LEF-10 and the LEF-10S?
A: The LEF-10S has an All Call
button, which allows announcements to be made throughout the system when
the BG-10C and PS-1225UL are included with the system.
Q: Is the LEF System expandable
beyond 11 stations?
A: YES, using the LAF-C
Console Series master
station. The LAF-C Master may be expanded to call up to 120 stations, and
is listed as a Special Order Product. (LEF masters are only available
up to 10 stations.)
This is a commercial grade system only.
Back to top
LEM System
Q: Is the LEM System compatible
with the IE/IF Door Stations?
A: NO. Use LE- or
LS-series door stations or LE-series sub stations only.
Q: Are the LEM System
masters compatible with the LEF System masters?
A: NO, although both use
the LE-Series sub stations.
Q: Can the LEM System
be connected to a Paging System?
A: YES, with the BA-1
Paging Adapter and the appropriate sized amplifier.
Q: Are there any multiple
call door stations for the LEM System?
A: YES, the LE-B2, LE-B4,
LE-B6 and LE-B10, which are listed as Special Order Products.
Q: Is the NE-NVP/B Vandal
Resistant Door Station compatible with the LEM System?
A: NO. Use the LS-NVP/B.
Q: Is the RY-AC External
Signaling Relay compatible with the LEM System?
A: YES, but the RY-AC will
require a 12V DC Power Supply (PS-1225UL). See the Systems Modification
Manual for details.
Q: Is the SP-5N Ceiling
Speaker compatible with the LEM System?
A: NO, use the SP-20N with an
NP-25V non-polarized capacitor (33mfd, 25V, Non-polarized).
Q: Is the LEM System compatible
with the MY Video Cameras?
A: NO.
Q: Can more than one LEM
Master be used in an application?
A: Only the LEM-1DL/C can
include multiple master stations. The LEM-1DL can be modified with the
DAK-2S Dual Master Adapter Kit. One adaptor kit allows one to call
two masters. Each master requires a separate power supply
(SKK-620 for LEM-1/3 and PT-1210N for LEM-1DL).
Q: Can more than one Sub
or Door Station be used with the LEM System?
A: The LEM-3 can have up to three
sub stations. The LEM-1 and LEM-1DL can only have one door station.
Back to top
CHIME-COM System
Q: Is the Chime-Com 2
(CC-1M) compatible with the CHIME-COM (C-ML/A)?
A: NO.
Q: Is the Chime-Com 2
compatible with the LE-Series or IE-Series Door Stations?
A: NO.
Only the door station sold with the kit (CC-DA) is compatible.
Q: Is the Chime-Com compatible
with the LE-Series Door Stations?
A: YES, the C-ML/A Master
station will work with any LE-Series Door Station. (Leave jumper between E
& - attached.)
Q: Is the Chime-Com compatible
with the IE-Series Door Stations?
A: NO.
Q: How many room stations
can be added to a Chime-Com System?
A: The Chime-Com and
Chime-Com 2 are designed for up to two inside stations. With the C-ML/A, one DAK-2S Dual
Master Adapter is required per system (2 masters). Each master station will require its own separate
power supply (SKK-620 or 4 "C" batteries). A total of 3 - 4 masters
may be used if they remain within the recommended distances for the system
(245' on 22AWG, shielded wire. 590' on 18AWG, shielded wire).
(NOTE: CCS-1A does not need the adapter kit, but is limited to two inside
stations.)
Q: How many door stations
can be added to the Chime-Com System?
A: Only one door station
should be used with the Chime-Com System. However, if a second door station
is needed on an existing system, an LE-D can be added (jumper in),
but both door stations will be
activated at the same time. Volume to the outside areas will be reduced,
and whatever sound is heard at each door location will be heard at
the master. The communication from
the master will be heard at both door stations simultaneously.
Q: What Power Supply is
used for the Chime-Com?
A: The Chime-Com
(C-123L/A) uses the SKK-620, 6V DC, 85mA Power Supply. Two SKK-620's are
required for the C-123LW, one per master.
Q: What Power Supply is
used for the Chime-Com 2?
A: The Chime-Com 2
(CCS-1A) uses the PT-1210N, 12V AC, 830mA Power Supply.
Q: Does the Chime-Com
2 have Door Release capability?
A: NO. Only the Chime-Com
has the door release feature.
Q: Can either of the Chime-Com
Systems be used with the MY Video Cameras?
A: NO.
Q: Can the Chime-Com System
connect to an External Signaling Device?
A: YES, using the RY-AC and a
separate 12V DC power supply. See the Systems Modification Manual for connection
information.
Back to top
NEM System
Q: Is the NEM System compatible
with the LE-Series Door Stations?
A: With modification, the LE-Series
Door Stations can be used with the NEM System. The PC-359B call holding
circuit board must be added, which requires solder connections. Otherwise,
use the NE-DA or NE-JA door
stations (SOP).
Q: Can
the NEM System be connected to an external signaling device?
A: YES, it may be
connected to an IER-2 call extension speaker, or a separate external device
using the TAR-3 External Signaling Device Relay and an SKK-620, 6V
DC 200mA power supply.
Q: How many stations can
be added to an NEM System?
A: The NEM System may
include up to two add-on selectors for a maximum capacity of 120 stations.
(If more stations are added, All Call will not function properly.)
Q: Is there a handset
substation for the NEM System?
A: The
NA-T/A handset is designed for the NEM System. It can be used in conjunction
with an open voice sub station,
giving the option of either open voice or handset communication at that
location.
Q: What Power Supply is used
for the NEM System?
A: The PS-2410A, 24V DC, 1A power
supply is used for NEM Systems of 20 or less stations. The PS-2420UL, 24V
DC, 2A power supply is used for NEM Systems with 21 - 40 stations.
Add-on selectors require their own separate
power supply, following the same rules as above.
Back to
top
MP-S System
Q: Is
the MP-S System compatible with the LE-series Sub Stations?
A: Yes, with modification. Please
refer to the Systems Modification Manual for more information.
Q: Can
the MP-S System be connected to a Paging System?
A: YES, with the BA-1P Paging
Adapter and appropriate sized amplifier.
Q: Is
the NE-NVP/B Vandal Resistant Door Station compatible with the
MP-S System?
A: NO, use the
LS-NVP/B. Note that when installing this unit with the AP-M, change the
switch position on each unit's PC board.
Q: Is
the RY-AC External Signaling Relay compatible with the MP-S System?
A: YES.
Q: Is
the SP-5N Ceiling Speaker compatible with the LEM System?
A: NO, use the SP-20N or any
standard 8ohm speaker with an NP-25V non-polarized capacitor (33mfd, 25V,
Non-polarized).
Q: Is
the MP-S System compatible with the MY Video Cameras?
A: NO.
Q: Can
more than one MP-S Master be used in an application?
A: The MP-S may be modified with
the DAK-2S Dual Master Adapter Kit. Each master will require a separate
power supply (PS-1225UL) and only one master can be used at a time.
Q: Does
the MP-S System have door release?
A: No, the MP-S System is only
capable of two-way audio communication.
Back to
top
AP-M System
Q: Is
the AP-M System compatible with the LE-series Sub Stations?
A: Yes, with modification. Please
refer to the Systems Modification Manual for more information.
Q: Can
the AP-M System be connected to a Paging System?
A: YES, with the BA-1P Paging
Adapter and the appropriate sized amplifier.
Q: Is
the NE-NVP/B Vandal Resistant Door Station compatible with the
AP-M System?
A: NO, use the
LS-NVP/B. Note that when installing this unit with the AP-M, change the
switch position on each unit's PC board.
Q:
Is the RY-AC External Signaling Relay compatible with the AP-M
System?
A: YES. Refer to the Systems
Modification Manual for more information.
Q:
Is the SP-5N Ceiling Speaker compatible with the AP-M System?
A: NO, use a standard 8ohm
speaker with an NP-25V non-polarized capacitor (33mfd, 25V, NP). Speaker
must be capable of handling 10 watts of power.
Q: Is
the AP-M System compatible with the MY Video Cameras?
A: NO.
Q: Can
more than one AP-M Master be used in a system?
A: Yes, two AP-M Masters can be
used to communicate with the same sub stations as well as communicate with
each other (master-to-master communication occupies a station number).
Q: Is the AP-M
System limited to 10 sub stations?
A: The standard AP-M is limited to 10
sub stations. A Special Order Product master (AP-10MS/C) is available for expansion
with an add-on selector. The add-on selectors are available in 10,
20 and 40 station sizes. (AP-10AS, 20AS, 40AS)
Back to
top
Handset
Products
IE System
Q: Is
the IE-1AD compatible with IE-1GD or IE-2AD?
A: NO, the IE-1AD is a maximum
one door, one inside station system.
Q: Is
the IE System compatible with the LE-Series Door Stations?
A: NO. Use any IE or IF series
door station.
Q: Is
the IE-1GD/IE-2AD compatible with the IE-8MD?
A: NO.
Q: How
many room stations can be added to an IE-1GD/IE-2AD?
A: Up to three IEH-1CD Room
Stations can be added to the IE-1GD/IE-2AD. (When an IER-2 is not included.
Max. 2 IEH-1CD's allowed when the IER-2 is used.)
Q: How
many room stations can be added to the IE-8MD?
A: up to five IE-8HD Room Stations
can be added to an IE-8MD for a total of six inside stations.
Q: What
Power Supply is used for the IE System?
A: The IE and IE-8 systems use
the PT-1210N, 12V AC, 830mA Power Supply.
Q: Does
the IE System have Selective Door Release capability?
A: The IE-8MD has Selective Door
Release Capability built in (2 doors). The IE-2AD requires the RY-3DL
for Selective Door Release.
Q: Is
the IE System compatible with the MY Video Cameras?
A: YES. For one camera, use the
MY-CU Main Monitor, and additional MYH-CU Monitors if needed. For two cameras,
use the MYW-P3CB adapter and the MYH-CU Monitor(s).
Q: Can
the IE System connect to an External Signaling Device?
A: YES, using the TAR-3 and a
separate 6V DC 200mA power supply (SKK-620).
Back to
top
VC
System
Q: Is
the VC System compatible with the VAM?
A: VC-K handsets can be used with
the VAM system, but the VA-K handsets are NOT compatible with the VC system.
Click HERE
for more information.
Q: Is
there any other style of room station for the VC system?
A: NO, the VC-K is the only room
station available.
Q: How
many locations can be selectively called with the VC System?
A: The VC System may include up
to 58 units. For larger applications, contact Aiphone's Technical Support Department.
Q: Can
more than one handset be used in a single apartment/unit?
A: The VC system is designed for
up to two handsets per apartment/unit. A third handset may be added with
a reduction in call tone.
Q: Is
video available with the VC system?
A: NO, use the GF system
for multi-unit video applications.
Back to
top
TD-H System
Q: Is
the TD-H system compatible with the older TB-F system?
A: Yes, with an NP-25V
non-polarized capacitor (33mfd, 25V, NP) installed between terminals C
and 1.
Q: Are
any door stations compatible with the TD-H system?
A: Yes. Use any of the IE or IF
series door stations with the DE-UR Door Station Adapter. Each door
station adapter occupies a channel. Up to two doors can be included in
a system.
Q: Is
video available with the TD-H system?
A: Yes, using the MY-series video
door stations, a DE-UR adapter, and either an MY-CU Monitor or the MYW-P3CB
with MYH-CU Monitors.
Q: How
many MY Cameras can be used with the TD-H system?
A: With the MYW-P3CB, two
MY-series cameras can be used. A third, video-only camera can be
added, as well as a standard CCTV camera.
Q: Is
there a desk mount terminal box available for the TD-H system?
A: Yes, the TDW series terminal
boxes will work with the TD-H system (TDW-1/A ~ TDW-24/A, matching the
number of channels on the handset).
Q: Are
there paging adapters for the TD-H system?
A: Yes, either the PD-1 paging
adapter or the PD-2 Talkback Paging Adapter is compatible with the TD-H system. Add
the appropriate sized amplifier. The Aiphone PG-20C, PG-50C and PG-100C
Paging Amplifiers have the PD-1 and PD-2 built in.
Q: Can
an external signaling device be added to the TD-H system?
A: Yes, using the RY-AC relay and
a separate power supply for the external device.
Back to
top
Video Products
MK and MY Products
Q: Is
the MYW-MD compatible with the MK-1MD?
A: The original MYW-MD is not
compatible, but the MYW-MD Type B (MYW-MD/B) IS COMPATIBLE with the MK-1MD
(and MK-1MD/A).
Q: Is
the MK-2DA compatible with the MY System?
A: YES.
Q: Will
the MYW-MD/Ab work in a system with the MK-2DA?
A: YES. The MYW-MD/AB can provide
video output from one MK-1MD/A monitor. If both inside monitors need video
output, then two adapters are required.
Q: Is
the MK-DS/B Camera compatible with the MY System?
A: YES. The
previous versions (MK-DS and MK-DS/A) were not, but the new MK-DS/B is
compatible.
Q: Are
other MY Cameras compatible with the MK-1MD/A?
A: YES, but only one monitor can
be used.
Q: Can
the new MK-1MD/A Monitors be added to an old style MK-1MD System?
A: YES, but the MK System can
only have a total of two monitors.
Original information can be found directly by the manufacturer at www.aiphone.com.
[ home ]
|